Adopted Codes and Local Criteria

International Residential Code

Codes adopted by reference can be viewed on the International Code Council website

Amendments apply to each of the adopted codes as described in Chapter 18 Article I-XIV of the Municipal Code. Please visit https://library.municode.com/co/fairplay/codes/municipal_code?nodeId=MUNICIPAL_CODE_CH18BURE for the current amendments. (Note: the latest ordinance may not be updated) Contact the Building Department with specific questions.

2018 International Building Code
2018 International Residential Code
2023 National Electrical Code
2018 International Mechanical Code
2018 International Plumbing Code as amended by the State Plumbing Board
2018 International Fire Code
2018 International Fuel Gas Code
2018 International Energy Conservation Code
2018 International Property Maintenance Code
2018 Wildland-Urban Interface Code

Local Design Criteria for the Town of Fairplay
(Note: Surrounding Park County has differing criteria)

Ground Snow Loado

Wind Design

Seismic Design Categoryf

Subject to Damage

 

Speed (mph)d

Topographic effectsk

Special wind regionl

Wind-borne debris zonem

Weatheringa

Frost line depthb

Termitec

 

65 PSF

 

115 MPH  ULT
Exposure C

Yes

No

No

B

Severe

48 inches

Slight to moderate

 

Winter Design Tempe

Ice Barrier Under-
layment Requiredh

Flood Hazardsg

Air Freezing Indexi

Mean Annual Tempj

 

 

2 F

Yes, entire roof surface

See Town adopted regulations and Article III

2500

32 F

 

Manual J Design Criterian

 

Elevation

Latitude

Winter heating

Summer cooling

Altitude correction factor

Indoor design temperature

Design temperature cooling

Heating temperature difference

9953 Ft.

39.22135 N

-14

81

.69

70 F

75 F

84

Cooling temperature difference

Wind velocity heating

Wind velocity cooling

Coincident wet bulb

Daily range

Winter humidity

Summer humidity

 

6

15 mph

7.5 mph

51

High (H)

50%

50%

 

 

Prescriptive Energy Code Values 

 

Windows and Doors

Skylight

Ceiling/roof assembly

Wood Framed Wall

Mass Wall

Floor

Basement Wall

Unheated Slab Edge

Heated Slab

Crawl space Walls

R-Values

N/A

N/A

49

20 + 5CI

Or

13 + 10CI

19/21

38

15/19

10 for 4ft depth

5

15/19

U-Factors

.30

.55

.026

.045

.057

.028

.050

N/A

N/A

.055

 